Maintenance 9. Troubleshooting
176 RC700 / RC700-A Rev.23
No. Message Remedy Note 1 Note 2
1001
Operation Failure.
Command parameter is invalid.
-
1002
accessed. The data is not set up
Check whether the target I/O,
variables, and tasks exist.
Enter the correct password.
1004
Cannot execute with unsupported
Use the correct version file.
1005
Cannot execute with invalid serial
number.
Use the backup data for the same
controller to restore the controller
1006
Cannot execute with invalid Robot
model.
Use the backup data for the same
controller to restore the controller
1007
Cannot execute with invalid
Use the supported installer.
1010
Remote setup error.
Cannot assign R-IO input number
Specify the input number excluding
the R-IO input number.
1011
Cannot assign a bit number which
does not exist to a remote I/O
signal.
Check the fieldbus slave size.
Check the fieldbus slave size.
1012
Cannot assign a bit number which
does not exist to a remote I/O
signal.
Check the fieldbus master size.
Check the fieldbus master size.
1013
Fieldbus slave failure.
Cannot change the size because it
currently includes a remote I/O
-
1014
Fieldbus master failure. Cannot
change the size because it
currently includes a remote I/O
-
1015
Remote setup error. Cannot assign
Hand-IO input/output number to
-
Cannot execute in recovery mode.
Boot the controller as normal.
1021
Cannot execute due to controller
Restore the controller configuration.
1022
Cannot execute without the project
Open a project.
1023
Cannot execute while the project is
open.
Rebuild the project.
Cannot activate from remote.
1025
Execution in Teach mode is
Change to the AUTO mode.
1026
Cannot execute in Teach mode
Change to the AUTO mode.
Cannot execute in Auto mode.
Change to the Program mode.
1028
Cannot execute in Auto mode
except from the main console.
Change to the Program mode.