Maintenance 9. Troubleshooting
RC700 / RC700-A Rev.23 177
No.
Message
Remedy
Note 1
Note 2
1030
Does not allow Operation mode to
be changed.
Change to the Auto mode with a
console in the Program mode.
1031
Cannot execute while tasks are
executing.
Stop the task and then execute.
1032
Cannot execute while the
maximum number of tasks are
executing.
Stop the task and then execute.
1033
Cannot execute during
asynchronous motion command.
Execute after the motion ends.
1034
Asynchronous command stopped
during operation.
The asynchronous command already
stopped when the controller received
a stop command.
1035
Cannot execute when Remote I/O
enabled except from the remote
device.
The command cannot be executed
by the console except the remote I/O
when AutoMode output of the remote
I/O is ON.
1037
Cannot execute when Remote
Ethernet enabled except from the
remote Ethernet device.
The command cannot be executed
by the console except the remote
Ethernet when Auto flag of the
remote Ethernet is ON.
1039 Execution is prohibited.
Prohibited command was executed
while executing the program.
Stop the program, and then execute
the command.
1041
Cannot execute during Emergency
Stop status.
Cancel the Emergency Stop status.
1042
Cannot execute while the
safeguard is open.
Close the safeguard.
1043
Cannot execute during error
condition.
Cancel the error condition.
1044
Cannot execute when the remote
pause input is ON.
Change the remote pause input to
OFF.
1045
Input waiting condition is the only
available condition to input.
The controller received an input while
it was not in the Input waiting
condition.
1046
Cannot execute during file transfer.
Execute after the file transmission.
1047
Cannot cancel the command
executed from other devices.
Cancel the motion command from the
device the command was issued
from.
1048
Cannot execute after low voltage
was detected.
Reboot the controller.
1049
Other devices are in program
mode.
Check connection of other devices.
1050 Password is too long.
Enter the password that is less than
16 characters.
1051 Export Controller Status failed.
1. Retry using the same USB
memory.
2. Retry using another USB
memory.
3. Retry after rebooting the
controller.
1052 Export Controller Status busy.
Execute the command after
completing the controller status
backup.
1053
Execution in Test mode is
prohibited
Execute in other modes.

Table of Contents

Other manuals for Epson RC700-A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Epson RC700-A and is the answer not in the manual?

Epson RC700-A Specifications

General IconGeneral
BrandEpson
ModelRC700-A
CategoryController
LanguageEnglish

Related product manuals