Maintenance 9. Troubleshooting
182 RC700 / RC700-A Rev.23
No. Message Remedy Note 1 Note 2
1421
Initialization failure.
Cannot allocate memory.
1422
Finalization failure.
Failed to finalization of controller.
Invalid conversion file path.
Invalid Command file path.
1427 Invalid Command file.
Update from Ver.7.4.0.2 or earlier to
Ver7.4.0.2 or later may fail.
1428
Failed to execute conversion of
program.
Rebuild the project.
Failed to write Prg file.
1501 Command did not complete in time.
Execute the command again after a
while. Check the connection
between the EPSON RC+7.0 and
1502
Communication disconnection
between RC+ and Controller.
Re-establish communication.
Check the connection between the
EPSON RC+7.0 and controller.
1:
Communicati
on timeout
2: USB cable
disconnection
3: USB
reception
failure
4: USB
communicati
1503
Disconnection while executing a
task.
Check the connection between the
console device and controller.
1504
Communication disconnection
between Remote Ethernet and
Controller. Re-establish
Check the connection between the
Remote Ethernet device and
controller.
1505
Communication disconnection
between Remote RS232 and
Controller. Re-establish
Check the connection between the
Remote RS232 device and controller.
1506
Communication disconnection
between TP3 and Controller.
Re-establish communication.
Check the connection between TP3
and controller.
1510 Out of IP Address range.
Check the IP address setting of the
controller.
1511 Reserved IP Address.
The IP address is reserved. Set the
other IP address.
1512 Reserved IP Gateway.
The gateway address is reserved.
Set the other gateway address.
1521
Vision communication.
Failed to initialize Ethernet.
Reboot the controller.
1522
Vision communication.
Failed to terminate Ethernet.
-
1523
Vision communication.
Failed to create the socket handle.
Reboot the controller.