Setup & Operation 12. I/O Remote Settings
70 RC700 / RC700-A Rev.23
(*1) AutoMode output ON is omitted from the table. This is an input acceptance condition for all
functions.
(*2) “Start inputexecutes Function specified by the following six bits: SelProg 1, 2, 4, 8, 16, and 32.
Function
SelProg1
SelProg2
SelProg4
SelProg8
SelProg16
SelProg32
Main
0
0
0
0
0
0
Main1
1
0
0
0
0
0
Main2
0
1
0
0
0
0
Main3
1
1
0
0
0
0
.
.
.
Main60
0
0
1
1
1
1
Main61
1
0
1
1
1
1
Main62
0
1
1
1
1
1
Main63
1
1
1
1
1
1
0=OFF, 1=ON
(*3) NoPause task” and “NoEmgAbort task” do not pause.
For details, refer to EPSON RC+ 7.0 Online Help or Pause in SPEL
+
Language Reference.
(*4) Turns OFF the I/O output and initializes the robot parameter.
For details, refer to EPSON RC+ 7.0 Online Help or Reset in SPEL
+
Language Reference.
(*5) The values specified by “SelRobot1, 2, 4, 8, and 16” correspond to the robot numbers.
Robot number
SelRobot1
SelRobot2
SelRobot4
SelRobot8
SelRobot16
0(All)
0
0
0
0
0
1
1
0
0
0
0
2
0
1
0
0
0
3
1
1
0
0
0
.
.
.
13
1
0
1
1
0
14
0
1
1
1
0
15
1
1
1
1
0
16
0
0
0
0
1
0=OFF, 1=ON
(*6) Initializes the robot parameter.
For details, refer to EPSON RC+ 7.0 Online Help or Motor in SPEL+ Language Reference.
(*7) For details, refer to EPSON RC+ 7.0 Online Help or MCal in SPEL+ Language Reference.
(*8) This is for experienced users only. Make sure that you fully understand the input specification before
using.
CmdRunning output and CmdError output will not change for this input.
“NoEmgAbort task” will not stop by this input.
When the input changes from ON to OFF, all tasks and commands will stop.
(*9) This function changes the output condition of MotorsOn, AtHome, PowerHigh, and MCalReqd.
By setting this signal with the condition selected using SelRobot1 - SelRobot16, you can switch the
output condition.
Once you select the condition, it will be kept until you change it or turn off / restart the Controller. All
manipulators are selected as default.

Table of Contents

Other manuals for Epson RC700-A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Epson RC700-A and is the answer not in the manual?

Epson RC700-A Specifications

General IconGeneral
BrandEpson
ModelRC700-A
CategoryController
LanguageEnglish

Related product manuals