Stylus Photo R1900/R2880/R2000/R2000s/SC-P400 Series Revision I
SC-P400 Series Adjustment 225
13. Confirm there is no dot missing in the nozzle check pattern on the bottom
of the color chart. If any are found, run a cleaning from the panel menu on
the printer, and then click [Print again].
14. After drying is complete (after 5 minutes has passed), click [Next] to go to
the measurement window.
Figure 9-14. Drying the Chart
15. Confirm the calibrator is connected, click [OK].
16. Place the calibrator on the white reference tile (white plate) and click [OK].
Figure 9-15. Preparing the Calibrator
5 min. later
Active in 5 min.
C A U T I O N
The white reference tile (white plate) on the calibration
plate should be clean. Clean off any dirt with alcohol or
other organic solvent. Use a soft cloth so as not to
damage the white reference tile (white plate).
The white reference tile (white plate) and the calibrator
are used as a pair. Do not use any other plate attached
with other calibrators.
C H E C K
P O I N T
When setting and measuring the color chart, orient the chart
with the letters printed on it to the left.