Epson Stylus Pro 7700/7710/7700M/7710M/7900/7910/9700/9710/9900/9910/WT7900/WT7910/9890/9908/7890/7908 Revision I
DISASSEMBLY & ASSEMBLY Disassembly and Assembly Procedure 239
Confidential
4.4.4.3 CR HP Sensor
1. Remove the Control Panel. (p203)
2. Remove the IC Cover R and the IC Shaft Cover R. (p206)
3. Remove the Maintenance Tank R. (p208)
4. Remove the Right Cover. (p209)
5. Unlock the Carriage Unit. (p201)
6. Move the Carriage Unit to the location where the CR HP Sensor can be removed.
7. Disengage the four hooks that secure the CR HP Sensor, and remove the CR HP
Sensor.
8. Disconnect the connector from the CR HP Sensor.
Figure 4-61. Removing the CR HP Sensor
C A U T I O N
When disconnecting the connector in the next step, take care not to
push it inside the printer.
- Right Side -
CR HP Sensor
Connector
Hook