7. Remove the three screws that secure the AID Board.
B) Silver, Phillips, Bind S-tite M3x6: three pieces
8. Remove the AID Board.
9. Disconnect the connector (CN2) and the FFC (CN1) on the AID Board.
Figure 4-150.
Removing the
AID Board
CN2
CN1
- Top right -
B
AID Board
The AID Board comes with the AID Board mounting plate and AID
Board Cover as a set. When installing the new AID Board to the
new main body, take out the board from them (secured with three
screws) and use only the board. Dispose the AID Board mounting
plate and AID Board Cover since they are not necessary.
A D J U S T M E N T
R E Q U I R E D
Be sure to refer to Chapter 5 “Adjustment” (see p351) and perform
specified adjustments after replacing or removing the AID Board.
<Adjustment Item>
1. Counter Clear (AID)
2. Cleaning PG Adjustment
3. AID Function Check
AID Board mounting plate