ADJUSTMENT Head Related Adjustments 395
Confidential
26. Make sure that the date and time printed in the second line on the upper left of the
chart (measurable time and date) is within the range displayed under the heading
“GMT” on the lower screen. (If the date and time is not within the range, it is
necessary to print the chart again.)
27. Refer to Figure 5-52, lay the chart on the black paper (or sheet) with the upper part
of the chart facing left side, and set the scanning ruler onto the bottommost patch
line.
Figure 5-52. Setting the Chart and the Scanning Ruler
Figure 5-53. Measurable Date and Time Check
S/N : 0000000000
2010-08-29 10:57 (GMT 2005-08-29 01:57)
2010-09-05 10:52(GMT 2005-09-05 01:52)
Chart2
Chart1
Version : XXXXXXXXXX
CVMMBGYORGRLGYYLVMLC
S/N : 0000000000
2010-08-29 10:57 (GMT 2005-08-29 01:57)
2010-09-05 10:52(GMT 2005-09-05 01:52)
Calibration
Patch
Main unit serial number
Printed date and time
Measurable date and time