T3-B T6-B Maintenance 5. Backup and Restore
T-B series Maintenance Manual Rev.1 25
Force Sensing I/F configuration
This check box allows you to restore the Force Sensing I/F configuration.
This is not selected by the default setting.
This function is not supported for T-B series Manipulator.
Password authentication settings
This check box allows you to restore the setting of authentication for PC
connection.
The authentication password for PC connection and the setting to
disable connection authentication are restored.
This is not selected by the default setting.
Click the <OK> button to restore the system information.
Restore the system configuration saved using Backup Controller only for the same system.
When different system information is restored, the following warning message appears.
Click the <No> button (do not restore data) except for special situations such a manipulator
replacement.
When restoring the backup including the robot information other than T-B series, an error
occurs.
You cannot restore the backup including T-B series robot created in the virtual controller of
EPSON RC+ 7.0 to the T-B series robot.