Front Panel Control
4-26
EN/LZT 790 0023/1 R16A
FPGA Temperature
FPGA Warning Temperature
The temperature in degrees centigrade of the host FPGA at which the
unit issues a warning.
FPGA Over Temperature
The temperature in degrees centigrade of the host FPGA at which the
unit issues a critical alarm.
FPGA Temperature The current temperature in degrees centigrade of the host FPGA.
PHY0 Temperature
PHY0 Warning Temperature
The temperature in degrees centigrade of the Ethernet PHY0 at which
the unit issues a warning.
PHY0 Over Temperature
The temperature in degrees centigrade of the Ethernet PHY0 at which
the unit issues a critical alarm.
PHY0 Temperature The current temperature in degrees centigrade of Ethernet PHY0.
PHY1 Temperature
PHY1 Warning Temperature
The temperature in degrees centigrade of the Ethernet PHY1 at which
the unit issues a warning.
PHY1 Over Temperature
The temperature in degrees centigrade of the Ethernet PHY1 at which
the unit issues a critical alarm.
PHY1 Temperature The current temperature in degrees centigrade of the Ethernet PHY1.
Mux SCR Source
Internal, Video. The source of the system clock reference used for
timing.
Status of Service The Setmode state of the unit.
Change State
Changes the Setmode state of the unit. The available options depend
on the settings in Advanced/System/Base Unit/MGP Support/MGP
Mode.
IP Input system Compensation 0 5000 ms
What to Do on Reboot
Restore, Offline. Determines whether the streams remain offline after
reboot or their Setmode state is to be restored.
TS Source IP Redundancy Non-Transparent, Transparent
BISS Mode BISS Security option (Normal or Advanced)
BISS Injected ID (14 hex digits)
BISS injected ID used for transmitting the Encrypted Session Word
used for BISS-E encoding.
BISS Keys table Table locations for BISS key storage and selection
UTC Time The UTC time set on the unit.
UTC Date The UTC date set on the unit.
SNTP Server The IP address of a time server in the network.
Reflex Version
1
Selects the Reflex version to use for statistical multiplexing. Not
supported in the current release.
DPI TCP Port The port for the SCTE104 Slice messages to be transmitted.
Alarm Status
The overall alarm status of the unit. The same as indicated by the light
pipe on the front panel.