B
11
630791 DS MKII INSTALLATION MANUAL
MODEL A B C D
DS1150
364 350 850
1508
DS1400 1800
DS1650 2094
B3 Hearth
Fireplace Glass
Fireplace
100mm
Min.
Flooring or Hearth
A hearth is not required. If a hearth is installed below the re, it must be at least 100 mm
below the boom of the glass or be composed enrely of non-combusble materials.
B4 Cavity Base
This appliance MUST be fully supported on its base, over the enre area of the underside
of the appliance. The base must also be level and strong enough to support the total
product weight, which is approximately 158 kg.
The replace can be recessed into the ground but must maintain clearances detailed in the diagram (shown
right) for any combusble ooring materials.
B5 Wall Linings
Only aer all applicable secons up to secon F9 on page 49 have been completed is it permissible to
commence with the nal wall linings detailed in secon F9 on page 49.
Wall lining cutout dimensions around the glass must be adhered to.
Please refer to secon F9 on page 49 for wall nishing dimensions surrounding glass.