The locaon of the horizontal powerue wall terminal must be installed in accordance with AS/NZS 5601 and
any other relevant building codes. If possible, avoid installing the horizontal powerue wall terminal in areas
exposed to high winds and extreme weather.
Some of the minimum clearances for a fan assisted wall terminal are listed below; please refer to AS/NZS 5601
Gas installaon standard for full guidance on the design of the ue system. Where possible allow a greater
clearance.
N
R
F
S
W
U
A
V
K
Q
E
J
J
A
H
E
D
C
C
A
O
G
J
L
B
M
P
Prohibited area for ues is
below or Distance 'E' to
the left and right of the
Electricity meter
or fuse box
M = Gas Meter
P = Electricity meter or Fuse box
H
A Below eaves, balconies and other projecons 200 mm
B From the oor, above a balcony or other surface 300 mm
C From a return wall or external corner 300 mm
D From a gas meter or regulator vent 1000 mm
E From electricity meter or fuse box 500 mm
F From a drain pipe or soil stack 75 mm
G Horizontally from any building structure or obstrucon 500 mm
H From any other ue terminal or combuson air intake 300 mm
J Horizontally from any moving window, door, non-mechanical air inlet, or any
other opening into a building with the excepon of sub oor venlaon
300 mm
K From a mechanical air inlet or spa blower 1000 mm
L Vercally below any moving window, door, non-mechanical air inlet, or any
other opening into a building with the excepon of sub oor venlaon
300 mm
N Horizontally from a roof light 600 mm
O Vercally from a roof light 500 mm
Q Vercally from a at roof 500 mm
R Horizontally from a vercal structure 500 mm
S Below a roof window 2000 mm
T Above or either side of a roof window 600 mm
U From a dormer window 1500 mm
V Above the apex of the roof (see note 1 on following page) 300 mm
W From an open ue 1500 mm