630791 DS MKII INSTALLATION MANUAL
C6 
The locaon of the horizontal powerue wall terminal must be installed in accordance with AS/NZS 5601 and
any other relevant building codes. If possible, avoid installing the horizontal powerue wall terminal in areas
exposed to high winds and extreme weather.
Some of the minimum clearances for a fan assisted wall terminal are listed below; please refer to AS/NZS 5601
Gas installaon standard for full guidance on the design of the ue system. Where possible allow a greater
clearance.
N
R
F
S
W
U
A
V
K
Q
E
J
J
A
H
E
D
C
C
A
O
G
J
L
B
M
P
Prohibited area for ues is
below or Distance 'E' to
the left and right of the
Electricity meter
or fuse box
M = Gas Meter
P = Electricity meter or Fuse box
H
A Below eaves, balconies and other projecons 200 mm
B From the oor, above a balcony or other surface 300 mm
C From a return wall or external corner 300 mm
D From a gas meter or regulator vent 1000 mm
E From electricity meter or fuse box 500 mm
F From a drain pipe or soil stack 75 mm
G Horizontally from any building structure or obstrucon 500 mm
H From any other ue terminal or combuson air intake 300 mm
J Horizontally from any moving window, door, non-mechanical air inlet, or any
other opening into a building with the excepon of sub oor venlaon
300 mm
K From a mechanical air inlet or spa blower 1000 mm
L Vercally below any moving window, door, non-mechanical air inlet, or any
other opening into a building with the excepon of sub oor venlaon
300 mm
N Horizontally from a roof light 600 mm
O Vercally from a roof light 500 mm
Q Vercally from a at roof 500 mm
R Horizontally from a vercal structure 500 mm
S Below a roof window 2000 mm
T Above or either side of a roof window 600 mm
U From a dormer window 1500 mm
V Above the apex of the roof (see note 1 on following page) 300 mm
W From an open ue 1500 mm