23
630791 DS MKII INSTALLATION MANUAL
D INSTALLING THE ELECTRICITY AND GAS TO THE APPLIANCE
D1
Before the Fireplace is installed, consideraon must be given to the locaon of an appropriate power supply. An
earthed 230/240 volt mains power connecon (typically a standard 3 pin outlet) must be available within 1m of
the boom right of the appliance.
This connecon must be accessible aer the heater has been fully installed so that the appliance can be safely
disconnected from the mains power supply prior to servicing.
A mains isolaon switch (compliant to AS:NZS 5601 Clause 6.2.8) which is accessible from outside the cavity can
also be used to disconnect the power.
Regardless of the method used, it MUST ALWAYS be possible to safely isolate the electrical supply to the
appliance aer it has been fully installed.
This appliance must not be located immediately below a socket outlet. This appliance will draw a maximum of 2
Amps from a 230/240 V supply. No addional power supply is required for the power ue.
An electrical wiring diagram is located underneath the electronic tray, on the rear of, and also in the rear of this
manual (Secon S15 on page 69).
D2
Download and install the Escea Smart Heat App
Ensure the replace and remote have been powered on, then follow the on screen instrucons (see below) to
connect the unit to the app.