630791 DS MKII INSTALLATION MANUAL
C INSTALLING THE FLUE
C1 
If your ue system is less than 8m long (as shown in diagrams below), then a simple aluminium exible ue is
required. If you wish to install a longer ue run, please contact the Escea Architectural Advisory Team.

The horizontal oset of the terminal can be any amount up to the total ue length listed below. Please
consult with Escea’s technical sta if your intended ue conguraon falls outside of the bounds of the ue
conguraons shown below.
NOTE: The fan in this powerue produces 52 DB of noise, think carefully around the locaon of the
terminal, if the terminal is in close proximity to the re then the fan noise will be more prevalent.
NOTE: If the only opon is to install the terminal close to the re then introducing sound deadening
material around the back of the terminal or stretching out the exiue and adding more S-bends is
recommended to reduce sound transfer through to the re.
Y
X
X + Y = 8m MAX
= 0.4m MIN*
* Excess noise may be present at this distance
8m MAX
1.2m F-F Liner
UVP Cowl
Liner
UVP Unit
8m MAX
NOTE: When ueing above the re, the pipe must slope towards re - NOT towards the terminal. Also
when ueing below the re, the pipe must slope towards the terminal - NOT towards the re.
X
Y
X + Y Maximum = 8m
Y Maximum = 1.5m
Y Minimum = 0m
X Maximum = 8m
X Minimum = 0m
X + Y Minimum = 0.4m