13
630791 DS MKII INSTALLATION MANUAL
C INSTALLING THE FLUE
C1
If your ue system is less than 8m long (as shown in diagrams below), then a simple aluminium exible ue is
required. If you wish to install a longer ue run, please contact the Escea Architectural Advisory Team.
The horizontal oset of the terminal can be any amount up to the total ue length listed below. Please
consult with Escea’s technical sta if your intended ue conguraon falls outside of the bounds of the ue
conguraons shown below.
NOTE: The fan in this powerue produces 52 DB of noise, think carefully around the locaon of the
terminal, if the terminal is in close proximity to the re then the fan noise will be more prevalent.
NOTE: If the only opon is to install the terminal close to the re then introducing sound deadening
material around the back of the terminal or stretching out the exiue and adding more S-bends is
recommended to reduce sound transfer through to the re.
Y
X
X + Y = 8m MAX
= 0.4m MIN*
* Excess noise may be present at this distance
8m MAX
1.2m F-F Liner
UVP Cowl
Liner
UVP Unit
8m MAX
NOTE: When ueing above the re, the pipe must slope towards re - NOT towards the terminal. Also
when ueing below the re, the pipe must slope towards the terminal - NOT towards the re.
X
Y
X + Y Maximum = 8m
Y Maximum = 1.5m
Y Minimum = 0m
X Maximum = 8m
X Minimum = 0m
X + Y Minimum = 0.4m