DS1150 PRODUCT SPECIFICATION
MODEL NAME DS1150
Descripon of Appliance Indoor Gas Fire Heater
Star Rang 4.4 Stars
Max Heat Output 8.2 kW
Compliant To AS/NZS 5263.1.3
Gas Type Natural Propane ULPG
Gas Input
High 34 MJ/hr 34 MJ/hr 34 MJ/hr
Low 25 MJ/hr 25 MJ/hr 25 MJ/hr
Inlet Pressure
Max 5.00 kPa 5.00 kPa 5.00 kPa
Min 1.13 kPa 2.75 kPa 2.75 kPa
Operang
Pressure
High 0.78 kPa 1.80 kPa 1.80 kPa
Low 0.30 kPa 0.90 kPa 0.90 kPa
Burner Jet Size
LH & RH 1.50 mm 0.85 mm 0.85 mm
Middle 1.95 mm 1.30 mm 1.30 mm
Burner
Aeraon
LH & RH Closed 2 x 4 mm 2 x 7 mm
Middle 1 x 3.5 mm 2 x 12 mm Spacer (Open)
Pilot Injector #37 #27 #27
Product
Dimensions
Width 1401 mm
Height 788 mm
Depth 379 mm
Weight 115.4 kg
Ignion System
Electronic Ignion to pilot system
Escea PCB
Ignion Acvaon 20 secs (approx)
Flame Safeguard Flame Reccaon
Consumpon 160 W @ 0.69 A 230 V
Remote Controls Yes
Timers Yes (App and Internet connecon compulsory)
Clock No
Funcon Lock / child No
Temperature Control Yes
Connecons
Electric 230 V AC
Gas 1/2" BSPT female lower centre of replace chassis
Flue Type Aluminium Flexi Flue
Flue Size (ID) 75 mm and 100 mm Flexi Flue and PolyPro
Spigot
Locaon
Top RH side
Data Badge Locaon On chassis base

Table of Contents