29
5-6-2. Checking Points after Power On
Checking point
Checking item
Method
Main motor
1. abnormal noise
ear
2. overheating
hand touch
Water pumping motor
1. abnormal noise
ear
2. obstacle drawn in
eye
Hydraulic motor
1. abnormal noise
ear
2. overheating
hand touch
Hydraulic pipe
1. oil leaking
eye
2. damage of pipe
eye
5-6-3. Normal Operation of Stop
Checking point
Checking item
Method
Emergency
1. all operation stopped
eye
2. proper location of EMERGENCY BUTTON(fixed at
lowest level)
eye
3. lift after rotation(released)
eye
Stop button
1. main motor stopped
eye
2. saw frame lifts when pressing STOP BUTTON
eye
Prompt switch of sawing break
prompt switch activated to stop main motor, saw
frame lifting
eye
Side protection cover of belt/wheel
opened
1. main motor/water pumper stopped
eye
2. return to standby mode after re-covering
eye