13-8. Electricity Not Supplied
ITEM 8
Malfunction
Electricity not supplied
Cause
a. Damaged fuse
b. Malfunction of Safety Switch
c. Damaged prompt switch of belt wheel cover, or bad connection of cover
d. Damaged control switch
Trouble
shooting
a. Check fuse and replace it if necessary, notice the current and voltage
b. Check the safety switch, or replace it if necessary
c. Check the prompt switch or replace it if necessary, check the cover and
adjust it properly
d. Replace the POWER ON/OFF switch if necessary
Remark
1. Repaired by qualified technician
2. Repair according to manual instruction
3. Contact local dealer/producer for parts supply if necessary
13-9. Frequent Damage of Fuse
ITEM 9
Malfunction
Frequent damage of fuse
Cause
a. Inadequate voltage
b. Short circuit
Trouble
shooting
a. Check the voltage
b. Check the circuit/isolation, or replace it if necessary
Remark
1. Turn off all power supply
2. Refer to manual instruction
13-10. Electricity Leakage
ITEM 10
Malfunction
Electricity leakage
Cause
a. Due to humidity or exposure of cable
b. Bad grounding
c. Damp shoe of operator, or wet site
Trouble
shooting
a. Check insulation, damp, dirt and modify them
b. Check proper earth
c. Keep away from damp
Remark
1. Repaired by qualified technician according to manual instruction
2. Keep away from humidity, with find insulation