67
13-8. Electricity Not Supplied
a. Damaged fuse
b. Malfunction of Safety Switch
c. Damaged prompt switch of belt wheel cover, or bad connection of cover
d. Damaged control switch
a. Check fuse and replace it if necessary, notice the current and voltage
b. Check the safety switch, or replace it if necessary
c. Check the prompt switch or replace it if necessary, check the cover and
adjust it properly
d. Replace the POWER ON/OFF switch if necessary
1. Repaired by qualified technician
2. Repair according to manual instruction
3. Contact local dealer/producer for parts supply if necessary
13-9. Frequent Damage of Fuse
a. Inadequate voltage
b. Short circuit
a. Check the voltage
b. Check the circuit/isolation, or replace it if necessary
1. Turn off all power supply
2. Refer to manual instruction
13-10. Electricity Leakage
a. Due to humidity or exposure of cable
b. Bad grounding
c. Damp shoe of operator, or wet site
a. Check insulation, damp, dirt and modify them
b. Check proper earth
c. Keep away from damp
1. Repaired by qualified technician according to manual instruction
2. Keep away from humidity, with find insulation