13-2. Not Start while Pressing “START” Button
ITEM 2
Malfunction
Not start while pressing START button
Cause
a. Damaged START button
b. Damaged fuse on main motor
c. Lack of phase on motor, bad connection on either cable among three
phases
d. Damaged red “STOP button
e. Malfunction of main motor
f. Overloading or damaged magnetic switch of main motor
Trouble shooting
a. Check the normality of START button, or replace it
b. Use meter to check the normality of fuse, or replace it
c. Check the proper connection of cables of motor, or secure it
d. Use meter to check STOP button, or replace it
e. Replace motor if necessary, ensure the proper installation with parallel
degree and adequate tension of belt
f. Replace magnetic switch of motor and check overloading device, refer to
manual instruction
Remark
1. Repaired by qualified technician, refer to manual instruction
2. Contact local dealer/producer for supply of parts if necessary
3. Adjust the consistency between overloading device and magnetic switch
13-3. Not Stop while Pressing “STOP” Button
ITEM 3
Malfunction
Not stop while pressing STOP button
Cause
a. Damaged red STOP button
b. Damaged vice START button
Trouble shooting
Use meter to check the button, or replace it if necessary, notice the proper
connections
Remark
1. Repaired by qualified technician
2. Contact local dealer/producer for parts supply if necessary