j. After cleaning up, restore the filter, pumper, get the cable outward to facilitate the cable connection later on
k. Use a 5mm T shape wrench to install pumper, and fix it on base
l. Use a cross driver to restore the cable, fix the isolation chip, to avoid damping
m. Put on the right and left protection covers and tighten them up, replenish in proper volume of cutting liquid
as following table:
Mixing ratio of cutting liquid (Mobilcut 102) against water 1:20
n. To avoid spilt liquid to slip and fall workers
o. Retrieve the caution mark and finish the maintenance