02006100 ZSME300000379
31
EXCELL PRECISION CO., LTD.
3-1-7
Operation Mode Settings
Select
in the General Function settings mode
to change the operation mode function settings.
C key clear parameter
Enter key perform action
Parameter settings:
00 Enter Simple Weight Mode after turn on
01 Enter Limit Weight Mode after turn on
02 Enter Target Weight Mode after turn on
03 Use previous setting mode after turn on
Factory default setting: 03
Press
Enter
key
Press
Enter
key
To exit the general
function settings, key in
00 and press
Enter
key.