CHAPTER 2 BASIC OPERATING FUNCTIONS
PH3 has three weight modes:
Simple, Limit and Target, press to
switch.
Simple weight mode
In this mode, the weight value can be displayed by means of analog and
digital. For example, when an object weighs 20 kg, the LCD2 shows the digits
20 and LCD1 has slight changes on its graduation.
Limit weight mode
This is a weight check mode, press “HI” and “LO” keys to input high and low
limit values, LCD1 displays if the weight on platter is greater than the high
limit, lower than the check value or equal to the OK range. When it meets the
OK range, the OK zone will blink. For example, High limit = 20, Low limit = 18,
then OK range is between 18 and 20.
Target weight mode
Use this mode to set a “Target” weight and an allowable range. When the
weight is within the range, it means the weight meets the target requirement.
For example, pour liquid into a container, press “OK” key to set target as 30
and press “Range” key to set an allowable range as ±2, when the weight
reaches the range between 28 and 32,the OK zone on LCD1 will blink.