RS1 07 & RS1 08 Settings Instruction
1. Under auto transmission mode, if RS1 07 and RS1 08 are all set at “00”, no matter what
weight it is, no any data of the weight will be transmitted out.
2. Under auto transmission mode, if RS1 07 is set between “00 ~ 99”, and RS1 08 is set at
“00”, when the weight is over or under the zero range that set in RS1 07, after being
stable, the data of weight will be transmitted out; if the weight is back to the zero range
(RS1 07,) and then becomes higher or lower than the range again, after being stable, the
data of weight will be transmitted out (the format is set in RS1 03.)
e.g.: When RS1 07 is set at “05”, RS1 08 is set at “00”, and RS1 04 is set at “02”, if the weight
is less than 5g, no data of weight will be transmitted out.
Put on a weight of 6g, after being stable ST, NT, +00000006g
If take off the weight of 6g, weight column displays “0g”
No transmission (because it’s in the zero range)
Put on a weight of 50g, after being stable ST, NT, +0000050g
If take off the weight “48g,” weight column displays “2g”
No transmission (because it’s in the zero range)
Add the weight to 30g, after being stable ST, NT, +0000030g
And so on…
3. Under auto transmission mode, if RS1 07 is set at “00” and RS1 08 is set between “00 ~
99”, as long as the weight is higher than “0”, after being stable, the data of weight will be
transmitted out. And then, the weight becomes the benchmark, as long as the weight
changes higher or lower than the range of RS1 08, after being stable, the data of weight
will be transmitted out. To sum up, on condition that the weight changes and after being
stable, the data of weight will be transmitted out (the format is set in RS1 03.)
4. Under auto transmission mode, if RS1 07 is set between “00 ~ 99” and RS1 08 is set
between “00 ~ 99”, as long as the weight is higher or lower than the zero range set in
RS1 07, after being stable, the data of weight will be transmitted out. To sum up, on
condition that the weight changes, not including “0”, after being stable, the data of weight
will be transmitted out (the format is set in RS1 03.