EasyManua.ls Logo

FAAC A952 - Page 90

FAAC A952
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A952 88 532310 - Rev.A
53
Number of cycles corrupted
Replace the board and carry out maintenance on the system.
x
56
Battery operation The notification remains as long as the automation is operating
on the battery due to a mains power failure.
x
58
Search for closing stop in progress Slow movement in progress while searching for the closing stop. x
60
Maintenance request Ask the installer to carry out scheduled maintenance. x
63
Intrusion attempt in progress A break-in attempt is in progress x
65
SETUP in progress SETUP is in progress. The notification remains as long as the
phase is in progress.
x
68
FAILSAFE slow movement
The automation moves at slow speed because the Test has failed on inputs
configured as safeties. Check that the safety detector is working. If the
problem persists, replace the device.
x
69
Door opened with semiautomatic Open The door is opened from the semiautomatic OPEN input. x
70
Low battery
The board detects that the charge level of the battery is too low for
movements to be carried out.
x
71
Intercom function active The board is in INTERCOM mode with other boards. x
72
Intercom fault No communication between the PRIMARY and the SECONDARY
board. Check the connections between the boards.
x
74
Interlock operation mode progress The automation is in INTERLOCK mode. x
80
Safeties in opening disabled
The safety in opening devices have been disabled (via Simply Connect).
x
81
Safeties in closing disabled
The safety in closing devices have been disabled (via Simply Connect).
x
84
Internal and external sensors disabled
The entry and exit sensors have been disabled (via Simply Connect).
x
86
BUS 2easy disabled BUS 2easy disabled (via Simply Connect). x
87
BUS 2easy devices registration in progress A registration procedure is in progress. x
90
Programming in progress Programming is being carried out (e.g. maintenance via Simply
Connect).
x
91
Accessory board awaiting FW update An accessory connected to the board is waiting for a FW update. x
95
Canbus node error
Error on one or more canbus nodes.
x
96
Non-standard programming The board appears to be programmed with values that are not
the default settings
x
97
Incorrect PRIMARY/SECONDARY configuration Check settings x
99
Control board data deletion All the data has been deleted from the E952CL board. x

Table of Contents

Related product manuals