157
CARE AND MAINTENANCE
16. Heating and ventila-
tion
Clean the paper filter (by blowing or tapping out)
about every six months or if fan output begins to
fall. Dry out if necessary.
Replace the paper filter if damaged. Do not
switch on the heater fan during spraying operati-
ons.
16.1 Removing the heater fan
filter
Operation_Pic_number:1
● Unscrew and remove the cover.
● Push latch (arrow) down and remove the fil-
ter.
● Ensure the correct positioning when instal-
ling.
Fig.53
16.2 Replacing the roof fan fil-
ter
Text-module
Operation_Pic_number:1
● Unscrew the screw plugs (arrowed), and flip
the panel upwards.
Operation_Pic_number:1
● Pull retaining clip (A) upwards.
● Open the clips (B) and take out the filter toget-
her with the filter frame.
Text-module
NOTE:
When closing, first disengage the retaining
clip.
WARNING:
A used pollutants filter may contain
traces of spraying agents. Replace
with a normal filter cartridge as soon
as possible after every spraying
operation.
Read the instructions leaflet
supplied with the filter.
Cab and filter do not guarantee 100%
protection against harmful
chemicals.
Keep the cab closed when using
sprays. Install a pollutant filter.
Observe the filter manufacturer's
maintenance instructions.
Fig.54
Fig.55