EasyManua.ls Logo

Fichet-Bauche KelNet Lock - 9 Factory Settings

Default Icon
59 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A0U571B - KelNet Lock - User Guide 9. FACTORY SETTINGS
53
9 FACTORY SETTINGS
The default factory settings are:
Identification /
code PIN
Rights Opening right Schedule
Super Manager 1
1 00000000
Enable
All
No
6
Manager 1
2 – 00000000 Enable
Change codes
3 to 19
Yes 1
Operator 01
to
Operator 17
3 - 00000000
à
19 00000000
Disable No Yes 1
Manager 2
2000000000 Disable
Change codes
21 to 29
Yes 2
Operator 1 Bio
to
Operator 9 Bio
21 – 00000000
à
29 – 00000000
Disable No Yes 2
CIT Manager
3000000000 Disable
Change codes
31 to 39
Yes 3
CIT Operator 1
to
CIT Operator 4
31 - 00000000
à
39 – 00000000
Disable No Yes 3
Super Manager 2
99 - 00000000
Disable
All
No
6
Schedules:
Schedule 1: from 6:00 am to 10:00 pm all days.
Schedule 2: from 6:00 am to 10:00 pm all days.
Schedule 3: from 6:00 am to 10:00 pm all days.
Schedule 6: from 0:00 am to 0:00 pm all days.
No annual schedule, no exceptional closed periods, no exceptional opening periods, and no public holidays
are defined.
Delays:
Open delay = 0 minute.
Duress alarm procedure delay = 10 minutes.
Emergency blocking delay = 30 minutes.
Automatic blocking delay after closing procedure = 0.
Time out for retracted bolt = 10 minutes.
General settings:
Duress alarm mode = last digit + X (default value: 0, therefore disabled) .
Wrong identification blocking rule = "Increasing blocking time".
No Interlocking rule.
No "4 eyes mode"
No closing procedure by identification.
No re-identification after delay time out.
No input / output function. Input I1 Door boltwork switch

Table of Contents