KelNet Lock - User Guide A0U571B
58
12 GLOSSARY
4 eyes mode
For this mode, two different users have to identify in order to validate an opening procedure or validate
access to the menus.
Angular filter
Optical filter placed on the display to limit the angular view (necessary for grade C).
Approval
Certification rate of the device. Under certain conditions, the approval can be lost (identification with
fingerprint only for example).
Audit
Chronological journal of events (also: "event log").
Biometric code
Code comprising human characteristics (fingerprint).
Bolt (or blocking feature)
Part of a HSL which, after inputting the correct opening code, moves, or can be moved, to either secure a
door or prevent movement of boltwork.
Boltwork
Blocking feature of a door. A boltwork switch informs if the door can be opened or not.
Centre national de prévention et de protection (CNPP)
National centre for risk prevention and protection.
CIT - Cash In Transfer
The transport, delivery and receipt of valuables.
Code
Identification information required which can be entered into a HSL and which, if correct, enables the
security status of the lock to be changed.
CT - Configuration Tool
Software running on PC which is used to configure all the parameters of the HSL.
Door status
The normalized status of a HSL door are:
• Closed door: door is within its frame ready for throwing its bolt(s).
• Bolted door: bolts are thrown.
• Locked door: boltwork cannot be withdrawn because of the HSL.
• Secured door: door is closed, bolted and locked with an HSL in the secured HSL condition.
Duress code
Parallel code which initiates some additional function (delay modification, alarm).
Event log
Chronological journal of events (also: audit).
G1 – Procedure G1
When a "procedure G1" is configured for an SU, identifications are not authorized. Activating this procedure
authorizes Access during an adjustable time (15 to 180’)’.
G2 – Procedure G2
When a "procedure G2" is configured for an SU and activated, the opening delay is cancelled.
G3 – Procedure G3
When a "procedure G3" is configured for an SU and activated, the current procedure is cancelled.
G4 – Procedure G4
When a "procedure G4" is configured for an SU and activated, the opening delay is replaced by a
"substitution" delay.
HSL - High Security Lock
Independent assembly normally fitted to doors of secure storage units, into which codes can be entered for
comparison with memorized codes (processing unit). A correct match of an opening code allows movement
of a blocking feature.