MS-9050 Series Manual — P/N 52413:F 10/22/2010 13
Features and Options Product Description
Communication Confirmation (Kissoff) LED
Touchtone/Rotary dialing
EIA-232 PC interface for local upload/download
80-character LCD display (backlit)
Real-time clock/calendar with daylight savings time control
History file with 500 event capacity
Advanced fire technology features:
Automatic drift compensation
Maintenance alert
Detector sensitivity test capability (NFPA 72 compliant)
Automatic device type-code verification
Point trouble identification
Waterflow selection per module point
Alarm verification selection per detector point
Walktest, silent or audible
PAS (Positive Alarm Sequence) per addressable detector and Pre-signal per point (NFPA 72
compliant)
Silence inhibit timer option per NAC
Autosilence timer option per NAC
Continuous, March Time, Temporal or California code for main circuit board NACs with two-
stage capability
Selectable strobe synchronization per NAC
Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or remote
annunciator
Auto-program (learn mode) reduces installation time. Reports two devices set to the same
address
Password and key-protected nonvolatile memory
User programmable password
Fully programmable from local keypad or optional keyboard
SLC operates up to 10,000 ft. (3,000 m) with twisted, unshielded fire wire
Compatible with Fire-Lite addressable devices (refer to the SLC Wiring Manual)
Compatible with legacy Fire-Lite 300 Series addressable devices (refer to the SLC Wiring
Manual)
Optional 4XTMF module (conventional reverse polarity/city box transmitter)
Optional ANN-I/O LED Driver module
Optional ANN-S/PG printer interface module
Optional ANN-80 remote LCD annunciator
Optional ANN-80C remote LCD indicator (for Canadian applications)
Optional ANN-LED Annunciator Module annunciates alarm, trouble and supervisory
Optional ANN-RLED Annunciator Module annunciates alarms only
Optional ANN-RLY Form-C Relay Module
Optional Dress Panel DP-51050 (a modified dress panel with the ANN-LED is included
standard with the MS-9050UDC)
Optional PRN-6F Serial Printer (requires ANN-S/PG module)
Optional PK-CD (contains PS-Tools) for local/remote upload/download of programming and
data