6.1.2 Machine Status Screen
In the top half of the screen it displays the
following information.
Size is the size of machine, (650mm = Large)
HVDC is for on line testing in the factory.
WL displays the water level in mm.
T is the actual temp of the inlet chamber water.
Target temp is the temperature selected.
In the lower half of the screen it displays the status of the following components.
Hot Valve (HOT)
Cold Valve (COLD)
Detergent Valve (DET)
Softener Valve (FAB)
SmartPump™ (PUMP)
Bleach Valve (Blch)
Component Testing
In this screen the components that are displayed can be tested. To test a component, firstly
highlight the component by using the left and right scroll arrows. To activate a component, press
the select button. To deactivate the component, depress the select button again.
Note: SmartPump™ can be tested in both the drain and recirculation modes. After
highlighting Pump, the first press of the Select button activates the pump in the drain
direction, the second press activates the pump in the recirculation direction, a final press
turns the pump off.
6.2 Control Screen
6.2.1 Hot Bowl Flag
If the machine has been filled with the hot water valve utilised (i.e. warm or hot fill) and has not had
a cold rinse, the electronics will not allow the machine to spin up to its full speed of 1000 RPM. It
will only allow the spin speed to reach 700 RPM.
To remove this flag, enter the Control Screen mode and push the HI-EFFICIENCY button. This
flag can also be removed by putting the machine through a complete final rinse.