10.21 Removal of Recirculation Hose
(a) If the bowl is full of water drain or bail as
much of the water as possible from the
machine prior to continuing. To assist with
bailing the water, the inner bowl can be
removed.
(b) Follow procedures for removal of neck ring
(refer to Section
10.14).
(c) Lift the recirculation hose upwards and out
of its position on the outer bowl.
(d) Lay machine down or against a wall. If
leaning the machine against a wall ensure
that the machine is stable, and take
necessary precautions not to damage the
wall or the machine.
(e) Depress the two ends of the clip and slide
the clip away from the pump housing.
(f) The hose can now be removed.
Reassembly:
Refit in the reverse manner, ensuring the recirc
hose clip faces away from the cabinet.