EasyManuals Logo

Fisher & Paykel AQUASMART WL37T26CW2 User Manual

Fisher & Paykel AQUASMART WL37T26CW2
79 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #50 background imageLoading...
Page #50 background image
478182
50
60. (00111100) Motor Control Memory Check Fault
On power up, the Motor Control Module has checked its memory against a known
reference and found differences.
Primary Source: Motor Control Module.
Action: Replace Motor Control Module.
68. (01000100) Pressure Transducer Error – Count Too High
69 (01000101) Pressure Transducer Error – Zero Too Low
70 (01000110) Pressure Transducer Error – Zero Too High
72. (01001000) Pressure Transducer Error – Maximum Positive Drift
The pressure transducer sensor is faulty or damaged.
Primary Source: Motor Control Module.
Action: Replace Motor Control Module.
104. (01101000) See Fault Code 106
105. (01101001) Comms Error Time Out
These faults are reported when the Display Module detects an error in the communications
between the Display Module and the Motor Control Module. Can also occur when display
change with the power still on.
Primary Source: Display Module.
Action: Replace Display Module.
Secondary Source: Motor Control Module.
Action: Replace Motor Control Module.
Tertiary Source: Rotor Position Sensor
Action: Replace Rotor position Sensor. If this corrects the fault refit the
original Display Module and/or Motor Control Module.
106. (01101010) Display Module to Motor Control Module Communications Error
These faults are reported when the Display Module detects an error in the communications
between the Display Module and the Motor Control Module.
Primary Source: Display Module.
Action: Replace Display Module.
Secondary Source: Motor Control Module.
Action: Replace Motor Control Module.
107. (01101011) Motor Control Module Reset Error
The Display Module has detected that the Motor Control Module has reset when it should
not have. This can be due to a Motor Control Module supply disturbance or microprocessor
failure.
Primary Source: Motor Control Module.
Action: Replace Motor Control Module.
108. (01101100) Comms CRC Error – See Fault Code 106
110. (01101110) Motor Bridge Thermistor Open Circuit
111. (01101111) Motor Bridge Thermistor Short Circuit
The motor bridge thermistor is faulty or damaged
Primary Source: Motor Control Module.
Action: Replace Motor Control Module.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fisher & Paykel AQUASMART WL37T26CW2 and is the answer not in the manual?

Fisher & Paykel AQUASMART WL37T26CW2 Specifications

General IconGeneral
BrandFisher & Paykel
ModelAQUASMART WL37T26CW2
CategoryWasher
LanguageEnglish