478182
54
Secondary Source: Motor.
Action: Check continuity of motor phases. Check the bridge terminal on the
stator is not open circuit or burnt. Replace Stator.
Tertiary Source: Rotor Position Sensor.
Action: Check the Rotor Position Sensor patterns with a RPS Tester. If faulty
fit new Rotor Position Sensor.
Quaternary Source: Motor Control module.
Action: Replace the Motor Control Module.
245. (11110101) Smart Pump Stall
This fault is normally as a result of the pump stalling during its normal operation.
Primary Source: Pump stator winding open circuit.
Action: Check the resistance of the pump stator. Resistance per Phase:
8.1Ω +/- 10% (16.2Ω +/- 10% across any two phases).
Secondary Source: Pump System.
Action: 1. Check that the drain hose has not been kinked.
2. Check the length of the drain hose. A 1 metre extension hose of
the same diameter fitted to the existing drain hose is the
maximum allowable length.
3. Check that the machine is not pumping to a head that exceeds the
pump’s limits (2.4 meters is maximum head height).
4. Remove the inner bowl and check that the pump hood hasn’t been
fitted around the wrong way.
5. Check for lint streaming from the pump hood that may be blocking
the cap inlet.
6. Remove the pump hood and cap. Check for lint, grit and debris.
7. Check for free movement of the flapper and that the impeller hasn’t
come off the rotor.
8. Check for free movement of the flapper (replace if broken).
9. Check for lint and foreign objects in the ports of the pump housing.
Tertiary Source: Motor Control Module.
Action: Replace Motor Control Module.
246. (11110110) Bleach Valve Fault
The Motor Controller module has detected that the Bleach valve (red clip) is faulty. It
determines this by measuring voltages from the valve diagnostic circuit. The most likely
cause is that the valve harness has not been connected correctly or the valve is open
circuit.
Primary Source: Wiring.
Action: Check the valve harness is correctly fastened to the valve or the pins
are not bent backwards.
Secondary Source: Bleach Valve.
Action: Check the valve coil is not faulty (i.e. not open circuit – See 1.8).
Tertiary Source: Motor Controller module.
Action: Replace the Motor Controller module.
247. (11110111) Smart pump Flapper Fault
The Motor Control Module has registered a drop in the water level during the recirculation
phase of the wash cycle. Water is being drained instead of recirculating. The most likely
cause is that the flapper is stuck in the drain position.
Primary Source: Flapper valve.
Action: Check for free movement of the flapper valve (replace if broken or
damaged).