DC100 MAX Digital Dispenser Operating Manual
© 2023 Fisnar - 77 - DC100 MAX Rev 4
Command
Read (R) / Write (W)
Parameter Address Value Data Value
R / W
Dispensing
0x0001
0 1 (Hex)
R / W Program Number 0x0002 1 16 (Hex)
R / W Mode 0x0003 1 – 5 (Hex)
R / W
Time P1 P16
0x0100 … 0x010F:
0000 9999 (Hex)
R / W
Time Decimal Place
Position P1 P16
0x0110 … 0x011F: 1-3 (Hex)
R / W Delay Time P1 P16 0x0120 … 0x012F: 0000 9999 (Hex)
R / W
Delay Time Decimal
Place Position P1 P16
0x0130 … 0x013F: 1-3 (Hex)
R / W Mode P1 P16 0x0140 … 0x014F: 1-5 (Hex)
R
Pressure kPa
0x8001
Integer Number
R
Pressure inHg
0x8002
Integer Number
R Pressure kPa 0x8003 Integer Number
R Vacuum kPa 0x8004 1 Decimal Place
R
Vacuum inHg
0x8005
2 Decimal Place
R Vacuum kPa 0x8006 Intger Number
Alarm Status 0x8007 (convert returned Hex value to Binary Value)
R
Dispense Limit Alarm
Bit 0
R Glue Alarm Bit 1
R Pressure Alarm Bit 2
R
Vacuum Alarm
Bit 3
R Input Alarm Bit 4
Machine Input Status 0x8008 (convert returned Hex value to Binary Value)
R CC Stat Initialise Bit 0
R Input Alarm Bit 1
R
24V Start Initialise
Bit 2
R
Clear / Reset
Bit 3
R Bit 0 Signal Bit 4
R Bit 1 Signal Bit 5
R
Bit 2 Signal
Bit 6
R Bit 3 Signal Bit 7
R Program Select Bit 8
R
Foot Switch
Bit 9