DC100 MAX Digital Dispenser Operating Manual
© 2023 Fisnar - 78 - DC100 MAX Rev 4
Command
Read (R) / Write (W)
Parameter Hex Value Input Value (x)
Machine Output Status 0x8009 (convert returned Hex value to Binary Value)
R Alarm Bit 0
R Busy Bit 1
R
End of Cycle
Bit 2
R
Ready
Bit 3
R Dispense Count P1-P16 0x8010 … 0x801F 0 9999
R
Total Cycles
0x8020 … 0x8021:
0 2147483647
R Used Time (hours) 0x8022 … 0x8023 0 999999999
R Used Time (minutes) 0x8024 0 59
R
Used Time (seconds)
0x8025
0 59
R
Software Version
0x8026
V1.0
R / W
Clear
0xAAAA
0 3
R / W
Save
0xABCD
0 1
Command Code Error + 0x80
Error
Command Code
Incorrect
0x01
Error Data Address Incorrect 0x02
Error
Data Incorrect or Value
out of range
0x03