15 Data transmission
FLUXUS F502TE 15.3 Transmission parameters
107
UMFLUXUS_F502TEV1-5EN, 2020-05-29
15.3 Transmission parameters
• the transmitter sends CRLF-terminated ASCII
• max. line length: 255 digits
RS232
default: 9600 bits/s, 8 data bits, even parity, 2 stop bits, RTS/CTS protocol (hardware handshake)
The transmission parameters of the service interface RS232 can be changed.
• Enter the HotCode 232-0- (see section 8.4).
• Set the transmission parameters in the 4 scroll lists.
• Press ENTER.
– baud: baud rate
– data: number of data bits
– par: parity
– st: number of stop bits
RS485
default: 9600 bit/s, 8 data bits, even parity, 1 stop bit
• Select the menu item Special Funct.\SYSTEM settings\Network to change the settings of the transmission
parameters.
• Press ENTER.
This display will only be indicated if the transmitter has an interface RS485.
• Press ENTER to confirm the device address in the network.
• Select default to display the default transmission parameters.
• Select setup to change the transmission parameters.
• Press ENTER.
• Set the transmission parameters in the 3 scroll lists.
• Press ENTER.
– baud: baud rate
– parity: parity
– st: number of stop bits
The default transmission parameters will be used if default is selected and the transmission parameters have not been
changed.
Special Funct.\SYSTEM settings\Network
Special Funct.\SYSTEM settings\Network\Device address
Special Funct.\SYSTEM settings\Network\RS485 protocol
BAUD<data par st
9600 8bit EVEN 2
BAUD< parity st
9600 EVEN 2