7 Connection
7.1 Transducers FLUXUS F502TE
2020-05-29, UMFLUXUS_F502TEV1-5EN
48
Remove the blind plug for the connection of the transducer cable.
Insert the transducer cable into the housing.
Fix the transducer cable by tightening the cable gland.
Connect the transducer cable to the terminals of the transmitter (see Fig. 7.3 and Tab. 7.2).
Fig. 7.3: Connection of the transducer cable with plastic jacket and stripped ends to the transmitter
1 cap nut
2 compression part
3 basic part
4 external shield, brushed back
Tab. 7.2: Terminal assignment
terminal connection
AV transducer (brown cable, marked white)
AVS transducer (red cable)
ARS transducer (red cable)
AR transducer (brown cable)
AV
AVS
AGN
ARS
AR
70 mm
20 mm
10 mm
4
cable gland
1 2 3