16 Technical specifications &
dimensional drawings
➲ FLIR Systems reserves the right to discontinue models, parts and accessories, and
other items, or change specifications at any time without prior notice.
16.1 Imaging performance
1.3 mradSpatial resolution
± 2 °C/± 3.6 °F or ± 2 % of readingAccuracy
50/60 Hz, non-interlacedImage frequency
Automatic or manualFocus
Adaptive digital noise reductionDigital image enhancement
16.2 Detector
Focal Plane Array (FPA), uncooled microbolome-
ter,
320 × 240 pixels
Type
7.5–13 μmSpectral range
16.3 Image presentation
Built-in, high resolution color LCD (TFT)Viewfinder
16.4 Temperature ranges
Temperature range is subject to customer config-
uration, and/or three-digit camera type number.
Refer to the camera menu system to see available
temperature ranges.
Temperature range
16.5 Correction parameters
Set by number.Emissivity correction
Automatic, based on input from distance, atmo-
spheric temperature, and relative humidity.
Atmospheric transmission correction
Automatic, based on signals from internal sensorsOptics transmission correction
16