Operation
Menu Structure
45
6
6.2.1 Information Menu
The INFORMATION MENU consists of the following subentries which are not user modifiable and for information
purpose only. All items marked in red are exemplary entries.
INFORMATION
(1-color mode)
INFORMATION
(2-color mode)
1-Color 43.5°C
E=1.000 Av:0.2s
2-Color 43.5°C
S=1.000 Av:0.2s
INTERNAL TEMP.
23.5°C
INTERNAL TEMP.
23.5°C
ATTENUATION
100%
LOW LIMIT
400°C
LOW LIMIT
400°C
HIGH LIMIT
1800°C
HIGH LIMIT
1800°C
SENSOR IDENT
E1ML-F2-V-0-0
SENSOR IDENT
E1RL-F2-V-0-0
SENSOR REVISION
2.02.28
SENSOR REVISION
2.02.28
SERIAL NUMBER
37560001
SERIAL NUMBER
37560001
MAC ADDRESS
001d8d200364
MAC ADDRESS
001d8d200364
INFO FIELD
shows essential information for the sensor such as:
Operation mode: 1-color or 2-color
Internal temperature in °C or °F
Emissivity setting (1-color mode) or Slope setting (2-color mode)
Signal processing function Av: average, Ph: peak hold, Vh: valley
INTERNAL TEMP.
displays the internal device temperature in °C or °F (e.g. 39.8°C)
ATTENUATION
The subentry is only available for sensors in 2-color mode. A percentage value of the measured attenuation will
be displayed (e.g. 10%).