PV series Solar Pumping Inverter
- 30 -
F11.10
Selection of failsafe
action 1
Ones: Bus Under voltage
ProtectionErr07)
0:Reporting faults and freely
parking
1:Alarming and parking by
deceleration mode
2:Alarm and continue running
on fault frequency
3:Protection Invalid
03000
×
Tens: Input Phase-protection
(Err09)
Hundreds: Output
Phase-protection (Err10)
Thousands: Motor Overload
Protection (Err10)
Myriabit: Inverter Overload
ProtectionErr12)
F11.11
Selection of failsafe
action 2
Ones: External Input
Failure-protectionErr13
0:Reporting faults and freely
parking
1:Alarming and parking by
deceleration mode
2:Alarm and continue running
on fault frequency
3:Protection Invalid
00000
×
Tens: Memory Failure (Err15)
Hundreds: 485 communication
timeout (Err18)
Thousands: PID feedback
disconnection when running
Err19
Myriabit: running time arrives
Err20