PV series Solar Pumping Inverter
- 31 -
F11.12
Selection of failsafe
action 3
Ones: Disconnection Fault of
Temperature SensorErr24
0:Reporting faults and freely
parking
1:Alarming and parking by
deceleration mode
2:Alarm and continue running
on fault frequency
3:Protection Invalid
00
×
Tens: Inverter load-lostErr25
F11.14
When failure, frequency
selection of continue
running
0Running on current setting
frequency
0
×
1Running on setting frequency
2Running on upper-limit
frequency
3Running on lower-limit
frequency
4Running on abnormal
spare-frequency
F11.15
Abnormal Alternate
Frequency
0.00Fmax
0.00Hz
×
F11.17
Protection time of Motor
Overload
30.0300.0s
60.0s
×
F11.18
Selection of Overload
Pre-warning
Ones: selection of detection
0always detection
1detection only when constant
speed
00
×
Tens: condition selection of
detection
0responds to rated current of
motor
1responds to rated current of
inverter
F11.19
Detectable Level of
Overload Pre-alarm
20.0200.0%
130.0%
×
F11.20
Detectable Time of
Overload Pre-alarm
0.160.0s
5.0s
×
F11.21
Pre-alarm Temperature
50.0100.0
70.0
×