CAR menu
Parameter Function
40cm/min
Travel Speed
Denes the traversing speed of the carriage in cm/min.
Unit: cm/min
Setting range: 5 to 200 cm/min
0cm
Total Path
The total path for welding. Once this distance has been reached,
the program will stop automatically.
Unit: cm
Setting range: 0 to 9999 cm
0cm
Segment Width
Denes the length of the segments to be welded.
Unit: cm
Setting range: 0 to 99.9 cm
0cm
Segment Gap
Denes the length of the segments not to be welded.
Unit: cm
Setting range: 0 to 99.9 cm
0.0s
Start Delay / Flying Start
Unit: s
- Setting range: 0 to +5 s ... Start Delay:
Denes the time between ignition of the arc and commence-
ment of carriage movement.
- Setting range: 0 to -5 s ... Flying Start:
Denes the time between commencement of carriage move-
ment and ignition of the arc.
CAR
OSC
000
Slot 0
Menu entry:
1. Turn menu adjusting dial and highlight the CAR
menu (white frame).
2. Press the menu adjusting dial once.
Carriage parameters
23