OSC menu
Parameter Function
50%
Oscillation Speed
Traversing speed for oscillation in %.
Setting range: 5 to 100%
30%
Oscillation Path
Denes the distance between left and right reversal points of the
oscillation motion.
Setting range: 5 to 100%
CAR
OSC
000
Slot 0
Menu entry:
1. Turn menu adjusting dial and highlight the OSC
menu (white frame).
2. Press the menu adjusting dial once.
Parameter Function
0.0s
Back Filling
Denes for how long the torch should weld backwards at the end
of the weld.
Setting range: 0 to 5 s / ON / OFF
0.0s
End Crater Filling
Length of time that the carriage pauses at the end of the weld
seam to ll the end-crater. Value must be the same or higher
than the entered value on the power source (nal current dura-
tion).
Setting range: 0 to 5 s
O
Change direction / Stop
- ON ... Once the limit switch has been reached, the carriage
reverses and runs to the other limit switch.
- OFF ... Once the limit switch has been reached, the carriage
stops
CAR menu
(continued)
24