OSC menu
Parameter Function
Slot 0
CAR
OSC
50%
Oscillation Speed
Traversing speed for oscillation in %.
Setting range: 5 to 100%
Slot 0
CAR
OSC
30%
Oscillation Path
Denes the distance between left and right reversal points of the
oscillation motion.
Setting range: 5 to 100%
CAR
OSC
000
000
Slot 0
Menu entry:
1. Turn menu adjusting dial and highlight the OSC
menu (white frame).
2. Press the menu adjusting dial once.
Parameter Function
Slot 0
CAR
OSC
0.0s
Back Filling
Denes for how long the torch should weld backwards at the end
of the weld.
Setting range: 0 to 5 s / ON / OFF
Slot 0
CAR
OSC
0.0s
End Crater Filling
Length of time that the carriage pauses at the end of the weld
seam to ll the end-crater. Value must be the same or higher
than the entered value on the power source (nal current dura-
tion).
Setting range: 0 to 5 s
Slot 0
CAR
OSC
O
Change direction / Stop
- ON ... Once the limit switch has been reached, the carriage
reverses and runs to the other limit switch.
- OFF ... Once the limit switch has been reached, the carriage
stops
CAR menu
(continued)