Insulation settings Insulation warning:
to activate and deactivate the insulation monitoring with dis-
play of a warning without interrupting feed-in in the event of an
insulation error
ON / OFF (depends on the country setup)
Threshold warning:
to set an insulation threshold below which the inverter displays
a warning (without interrupting feed-in)
depends on the country setup set
Threshold error:
to set an insulation threshold under which the inverter displays
an error message and interrupts feed-in
depends on the country setup
TOTAL Reset ... resets the max. and min. voltage values and the max. power
of feeding in in the LOG menu item to zero.
Once you have reset the values, this cannot be undone.
To reset the values to zero, press the "Enter" key.
"CONFIRM" is displayed.
Press the "Enter" key again.
The values are reset and the menu is displayed.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Primo Series and is the answer not in the manual?

Fronius Primo Series Specifications

General IconGeneral
EfficiencyUp to 98.1%
Protection RatingIP65
Operating Temperature Range-25°C to +60°C
Frequency50 / 60 Hz
DC input voltage range80 - 600 V
ModelPrimo Series
TypeTransformerless
Power Classes3.0 kW to 8.2 kW
Communication InterfacesWLAN, Ethernet, RS485
Weight21.5 kg
Max. apparent AC power8, 200 VA
AC voltage range150 - 280 V
MPP voltage range240 - 480 V
Warranty5 years
Dimensions645 x 431 x 204 mm