EasyManuals Logo

Fronius TransTig 1700 User Manual

Fronius TransTig 1700
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #59 background imageLoading...
Page #59 background image
Special 4-step
mode:
variant 4
Variant 4 of the special 4-step mode is activated when the SFS set-up parameter
is set to "4".
-
Welding start-up and welding: briefly pull back and release the torch trigger -
the welding current will rise at the specified upslope value from the starting
current I
S
until it reaches the main current value I
1
.
-
Push forward and hold the torch trigger for intermediate lowering
-
Release the torch trigger to resume the main current I
1
-
End of welding: briefly pull back and release the torch trigger
Special 4-step mode: variant 4