EasyManua.ls Logo

Frymaster easyTouch FilterQuick FQG60T - 2.1.3 Power Requirements; 2.1.4 Electrical Grounding Requirements

Frymaster easyTouch FilterQuick FQG60T
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-3
2. The appliance must be isolated from the gas supply piping system by closing its individual manual
shutoff valve during any pressure testing of the gas supply piping system at test pressures equal
to or less than ½ psi (3.5 kPa).
2.1.2.1 Installation Standards
1. U.S. installations must meet: 2. Canadian installations must meet:
American National Standard Institute CAN 1-B149 Installation Codes
ANSI Z83.11 Canadian Gas Association
American Gas Association 55 Scarsdale Road
8501 E. Pleasant Valley Road Don Mills, ONT, M3B 2R3
Cleveland, OH 44131
National Electrical Code Canadian Electric Code c22.1, part 1
ANSI/NFPA #70 Canadian Standards Association
American National Standard Institute 178 Rexdale Blvd.
1430 Broadway Rexdale, ONT, M9W 1R3
New York, NY 10018
NFPA Standards #96 and #211
National Fire Protection Association
470 Atlantic Avenue
Boston, MA 02110
3. CE/Export Standards: Fryer installation must conform with local codes, or, in the absence
of local codes, to the appropriate national or European Community (CE) standards.
2.1.3 Power Requirements
FQG60T FilterQuick™ easyTouch
®
Series gas fryers require 120VAC 60 cycle or 230VAC single-phase 50
Hz (International) electrical service and are equipped with a 16-3 SJT grounded flexible power cord for a
direct connection to the power supply. Amperage draw for each unit depends on the accessories
supplied with the unit/system.
DANGER
This appliance must be connected to a power supply having the same voltage and phase as speci-
fied on the rating plate located on the inside of the appliance door.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
2.1.4 Electrical Grounding Requirements
All electrically operated appliances must be grounded in accordance with all applicable national and
local codes, and, where applicable, CE codes. In the absence of local codes, the appliance must be
grounded in accordance with National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code,
CSA C22.2, as applicable. All units (cord connected or permanently connected) should be connected to a
grounded power supply system. A wiring diagram is located on the inside of the fryer door. Refer to the
rating plate on the inside of the fryer door for proper voltages.

Table of Contents