6-4
Problem Probable Causes Corrective Action
FQ4000 displays
TEMPERATURE PROBE
FAILURE.
Problem with the temperature measuring
circuitry including the probe or damaged
controller wiring harness or connector.
Shut the fryer down and call your FAS for
assistance.
Heating indicator is on,
but fryer is not heating.
Three phase power cord unplugged, or circuit
breaker is tripped.
Verify that all power cord(s) are fully seated in
their receptacle(s), locked into place and that
circuit breaker is not tripped If the problem
continues call your FAS for assistance.
FQ4000 displays RECOVERY
FAULT and alarm sounds.
Recovery time exceeded maximum time limit.
Clear error and silence the alarm by pressing the
button. Maximum recovery time for electric is
1:40. If this error continues call your FAS for
assistance.
FQ4000 displays NO MENU
GROUP AVAILABLE FOR
SELECTION
All menu groups have been deleted.
Create a new MENU group. Once a new menu is
created, add recipes to the group (see section
1.10 of the FQ4000 controller manual).
FQ4000 displays SERVICE
REQUIRED followed by an
error message.
An error has occurred which requires a service
technician.
Press X to continue cooking and call your FAS for
assistance. In some cases, cooking may not be
available.
6.2.3 Basket Lift Problems
PROBLEM PROBABLE CAUSES CORRECTIVE ACTION
Basket lift movement is
jerky and/or noisy.
Basket lift rods need lubrication.
Apply a light coating of Lubriplate
or similar lightweight
white grease to the rod and bushings.
6.2.4 Filtration Problems
Problem Probable Causes Corrective Action
Fryer filters after each
cook cycle.
Filter after setting incorrect.
Change or overwrite the filter after setting by
re-entering the filter after value in Manager
Settings, Filter Attributes in section 1.8 of the
FQ4000 controller manual.
Clean and Filter won’t
start.
Temperature too low.
Ensure fryer is at setpoint before starting a
Clean and Filter.
FQ4000 display shows
FILTER BUSY.
A. Another filtration cycle or filter pad change
is still in process.
B. Filter interface board has not cleared
checking system.
A. Wait until the previous filtration cycle
ends to start another filtration cycle.
Change filter pad if prompted.
B. Wait 15 minutes and try again.
Filter pump won’t start, or
pump stops during
filtering.
A. Power cord is not plugged in or circuit
breaker is tripped.
B. Pump motor has overheated causing the
thermal overload switch to trip.
C. Blockage in filter pump.
A. Verify that the power cord is fully plugged
in and the circuit breaker is not tripped.
B. If the motor is too hot to touch for more
than a few seconds, the thermal overload
switch has probably tripped. Allow the
motor to cool at least 45 minutes then
press the Pump Reset Switch (see section
2.1.2 of the FQ4000 controller manual).
C. Call your FAS for assistance.
Drain valve or return valve
stays open.
A. VIB board has failed.
B. Actuator has failed.
Call your FAS for assistance.