2-4
The equipotential grounding lug allows all the equipment in the same location to be
electrically connected to ensure there is no electrical potential difference between
the units, which could be hazardous.
DANGER
This appliance is equipped with a special (grounding) plug for your protection against electrical
shock and must be plugged directly into a properly grounded receptacle. Do not cut, remove, or
otherwise bypass the grounding prong on this plug!
DANGER
This appliance requires electrical power for operation. Place the gas control valve in the OFF
position in case of a prolonged power outage. Do not attempt to operate this appliance during a
power outage.
In the event of a power failure, the fryer(s) will automatically shut down. If this occurs, turn the power
switch OFF. Do not attempt to start the fryer(s) until power is restored.
2.1.5 Australian Requirements
To be installed in accordance with AS 5601 and AS/NZS 3000:2007, local authorities, gas, electricity, and
any other relevant statutory regulations.
If casters are fitted, the installation must comply with AS5601 and AS1869 requirements.
2.2 Caster/Leg Installation
On an appliance with casters; the installation shall be made with a connector that complies with the
Standard for Moveable Gas Appliances, ANSI Z21.69 • CSA 6.16, and a quick disconnect device that
complies with the Standard for Quick-Disconnect Devices for Use with Gas Fuel, ANSI Z21.41 • CSA 6.9.
2.3 Pre-Connection Preparations
DANGER
DO NOT connect this appliance to the gas supply before completing each step in this section.
After the fryer has been positioned under the exhaust hood, ensure the following has been
accomplished:
1. Adequate means must be provided to limit the movement of fryers without depending upon the gas
line connections. If a flexible gas hose is used, a restraining cable must be connected at all times
when the fryer is in use. The restraining cable and installation instructions are packed with the
flexible hose in the accessories box that was shipped with your unit.
DANGER
Do not attach an apron drainboard to a single fryer. The fryer may become unstable, tip over,
and cause injury. The appliance area must be kept free and clear of combustible material at all
times.