EasyManua.ls Logo

Frymaster easyTouch FilterQuick FQG60T - Routine Oil Changes (Saddle Oil Reservoir Only); Bulk Oil Systems

Frymaster easyTouch FilterQuick FQG60T
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-7
3. Put the tube in the new full container
(see Figure 6).
Figure 6
4. Press and hold the orange JIB reset switch five (5)
seconds to reset the top off system
(see Figure 7).
3.4.2.2 Routine Oil Changes (Saddle Oil Reservoir only)
1. Remove saddle oil reservoir lid.
2. Fill the oil saddle with oil.
3. Replace saddle oil reservoir lid.
4. Press and hold the orange ATO reset switch five (5) seconds to reset the top off system (see Fig-
ure 7).
The system is now ready for operation. As the fryer heats to preprogrammed temperatures, the
system will energize and then slowly add oil to the frypot as needed, until the oil reaches an opti-
mal level.
3.4.3 Bulk Oil Systems
Instructions for installing and using bulk oil systems are found in Appendix A located at
the rear of this manual.
Figure 7
WARNING:
Do not add HOT or USED oil
to a JIB or Saddle Oil Reser-
voir.

Table of Contents

Related product manuals