13-58 13. OMRON
Available Device Memory
The available setting range of device memory varies depending on the model. Be sure to set within the range available for the
model to be used. Use [TYPE] when assigning indirect device memory for macro programs.
Indirect Device Memory Designation
For bit designation, an expansion code setting is required.
00H: when designating bit 0 to 15
01H: when designating bit 16 to 31
PLC_CTL
Macro command “PLC_CTL F0 F1 F2”
Return data: Data stored from temperature controller to V series
*1 8000 (HEX): broadcasting
Device Memory TYPE Remarks
C0 Variable area (instantaneous value) 00H Double-word, read only
C2 Variable area (maximum value) 02H Double-word, read only
C3 Variable area (minimum value) 03H Double-word, read only
C000 Parameter area 04H Double-word
15 8 7 0
n + 0 Model (91 to 98) Device type
n + 1 Address No.
n + 2 Expansion code Bit designation
n + 3 00 Station number
Contents F0 F1 (= $u n) F2
Status read out
1 - 8
(PLC1 - 8)
n Station number
2
n + 1 Command: 06H
n + 2 Operation status
Operation instructions
1 - 8
(PLC1 - 8)
n
Station number
*1
3
n + 1 Command: 30H
n + 2
0300H: Integral power consumption zero reset
1200H: Maximum of each measurement value reset
1300H: Minimum of each measurement value reset
9900H: Software reset