15-4 15. Panasonic
FP-
Tool port setting
(Underlined setting: default)
*1 System register setting is enabled in the RUN mode.
COM port setting
(Underlined setting: default)
*1 System register setting is enabled in the RUN mode.
*2 For AFPG806COM1, set the switch attached to the back of the cassette as well.
SW1 to 2: OFF 19200 bps, ON 115 kbps
*3 In addition to system register setting, the station number setting is also possible with the station number setting switch. For more
information, refer to the PLC manual issued by the manufacturer.
FP1 / FP0 / FP-e
Tool port setting
(Underlined setting: default)
*1 System register setting is enabled in the RUN mode.
COM port setting
(Underlined setting: default)
*1 System register setting is enabled in the RUN mode.
System Register
*1
Contents
410 Unit No. 1
to 99
413
Data Length 7 / 8
bits
Parity None / Odd
/ Even
Stop Bit 1
/ 2 bits
415 Baud Rate 4800 / 9600
/ 19200 / 38400 /57600 / 115k bps
System Register
*1
Contents
COM1 COM2
410 411 Unit No.
1
to 99
*3
412 Communication Mode Computer link
413 414
Data Length 7 / 8
bits
Parity None / Odd
/ Even
Stop Bit 1
/ 2 bits
415 Baud Rate
4800 / 9600
/ 19200 / 38400 /57600 / 115k bps
*2
System Register
*1
Contents
411 Data Length 7 / 8
bits
414 Baud Rate 9600
/ 19200
- Parity Odd (fixed)
-Stop Bit1 (fixed)
System Register
*1
Contents
412 Communication Mode Computer link
413
Data Length 7 / 8
bits
Parity None / Odd
/ Even
Stop Bit 1
/ 2 bits
414 Baud Rate 4800 / 9600
/ 19200
415 Unit No. 1
to 99