15.1 PLC Connection 15-5
FP2
Tool port setting
(Underlined setting: default)
*1 System register setting is enabled in the RUN mode.
*2 Enabled when the DIP switch 1 on the back of the CPU unit is set to the OFF position.
COM port setting
(Underlined setting: default)
*1 System register setting is enabled in the RUN mode.
FP10/FP10s (COM Port)
Operation mode setting switch
Station number setting switch
(Underlined setting: default)
FP10SH (COM Port)
Operation mode setting switch (upper)
System Register
*1
Contents
411 Data Length 7 / 8
bits
414
Baud Rate
*2
4800 / 9600 / 19200 / 38400 / 57600 / 115200 bps
- Parity Odd (fixed)
-Stop Bit1 (fixed)
System Register
*1
Contents
412 Communication Mode Computer link
413
Data Length 7 / 8
bits
Parity None / Odd
/ Even
Stop Bit 1
/ 2 bits
414 Baud Rate 4800 / 9600 / 19200
/ 38400 / 57600 / 115200 bps
415 Unit No. 1
to 99
Switch Setting Contents
4 OFF Baud rate: 19200 bps
5 ON Data length: 8 bits
6ONWith parity
7OFFOdd
8OFFStop bit 1
Switch Setting
The tens place The ones place 01
to 32
Switch Setting Contents
1 OFF Not control with a modem
2 OFF Beginning code STX invalid
3OFF
Terminating code CR
4ON
5ONStop bit 1
6ON
Odd parity
7ON
8 ON Data length: 8 bits